COMMERCIALLY.× REAL BROKER INDUSTRIAL BAY RECORD · ALBERTA help@commercially.ca
Reference

Industrial bay specification reference

The dimensions, services and configurations you will encounter in multi-tenant industrial bays, in one place. These are conventional ranges for Western Canada — teaching figures, not a measurement of any building.

Size classes
6
Loading types
5
Source
Conventional practice
Applies to
No specific building
Anatomy

A bay in section

Roof deck / joists Clear height ≈ 24′ Structural bay ≈ 30′ Grade door Dock door 4′ deck

The three dimensions that decide what a bay can do: clear height to the lowest obstruction, the structural bay width between columns, and the loading arrangement at the wall.

Size

Bay size classes

Conventional market vocabulary, not a published standard. Every building draws its own lines.

Sizing guide →
Bay size classes
ClassTypical rangeWhat it holds
Micro bayUnder 1,000 sq ftThe smallest demised industrial unit — a single overhead door, a washroom, and little or no office. Trades storage, e-commerce fulfilment, service vans, hobby and workshop uses.
Small bay1,000 – 2,499 sq ftThe workhorse of multi-tenant industrial. One or two doors, a small front office, a washroom, sometimes a mezzanine. The size most trades, distributors and light manufacturers start in.
Mid bay2,500 – 4,999 sq ftTwo or more structural bays combined. Enough width for a forklift aisle and racking, enough office for a small team, and usually a second door.
Large bay5,000 – 9,999 sq ftThe top of the multi-tenant range. Often a corner unit with extra glazing, a dock plus a grade door, three-phase power and a built-out office and lunchroom.
Flex block10,000 – 24,999 sq ftSeveral bays taken together, or a small freestanding building. The point where a tenant starts to control its own yard, loading and signage.
Single-tenant building25,000 sq ft and upNo longer a bay. A whole building with its own loading court, sprinkler main and power service — priced, leased and managed on entirely different terms.
Height

Clear height and what it supports

Clear height guide →
Clear height ranges
Clear heightRackingTypically found in
Under 14 ftGround storage, two levels at bestPre-1970s stock, older converted space
14 – 17 ftTwo to three levels1960s–1980s multi-tenant buildings
18 – 22 ftThree levels comfortablyThe most common range in newer small-bay product
24 – 28 ftFour levelsLarger bays and newer multi-tenant buildings
30 ft and aboveDistribution gradeBig-box industrial, rare in bays
Loading

Loading configurations

Loading guide →
Loading types
TypeWhat it is
Grade / drive-in doorA door at floor level, driven straight into. The default in small-bay industrial.
Dock doorA door at trailer-deck height, roughly 48 inches above the apron, for van trailers.
Recessed / drive-down dockA ramp down to a dock in a building otherwise built at grade — common where a small bay must take a 53-foot trailer.
Dock plus gradeOne of each. The most flexible arrangement in a multi-tenant bay and the one that leases fastest.
No overhead doorStorage, showroom or office-only space inside an industrial envelope. Cheaper, but it is not a bay in any operational sense.
Typical door openings
DoorTypical clear openingNotes
Grade / drive-in10–14 ft wide × 12–16 ft highOlder buildings are often smaller. Measure the clear opening, not the frame.
Dock8–10 ft wide × 9–10 ft highOnly has to clear the trailer opening.
Dock heightAround 48 in above the apronVaries with trailer type; levellers absorb the difference.
Man door3 ft wideCheck it is not the only exit from the bay.
Services

Electrical service

Power guide →
Common electrical configurations
ServiceTypically runs
100A, single-phase, 120/208VLighting, receptacles, office, hand tools, a small compressor
200A, single-phase, 120/208VThe above plus a larger compressor and light shop equipment
200A, three-phase, 120/208VMost light manufacturing, welding, larger compressors, refrigeration
400A+, three-phase, 347/600VProduction equipment, large motors, paint booths, significant process load
Services

Heating, ventilation and fire protection

HVAC guide →
Systems you will encounter
SystemWhere it appears
Gas unit heaterThe default in multi-tenant bays. Simple, noisy, drafty.
Radiant tube heaterEfficient where doors open often. Needs clearance below.
Make-up air unitRequired wherever you exhaust significant air — spray, weld, cook, run engines.
Rooftop unitServes the office portion. Warehouse cooling is rare.
In-floor radiantNewer purpose-built space. Even and comfortable, slow to respond.
Wet sprinkler systemThe common arrangement. Designed for a specific commodity and storage height.
ESFRLarge-droplet ceiling suppression. Constrains what may hang below the heads.
In-rack sprinklersHeads inside the racking. Rearranging racks becomes a fire-protection change.
Checklist

What to measure at a viewing

  1. Clear height at the door, mid-bay, under the sprinkler main and under the lights — record the lowest.
  2. Clear opening width and height of every overhead door.
  3. Overall internal dimensions, and the position of every column.
  4. Office area separately from warehouse area, and the mezzanine if there is one.
  5. Electrical panel: photograph the label, the main breaker and the schedule.
  6. Gas meter and heater, including the service tag date.
  7. Sprinkler main, and ask what the system was designed for.
  8. Floor drains, and what serves them.
  9. Apron depth outside each door, and the slope.
  10. Assigned parking stalls and any yard.
Questions

About this reference

Are these the dimensions of a specific building?

No. Every figure here describes how industrial bays are commonly built in Western Canada. Nothing on this page measures any particular building, and the datasets used here do not establish these dimensions. Measure the space you are considering.

Can I rely on these figures for a design?

No. They are for orientation — to help you ask the right questions and recognise when a space is unusual. Any design decision needs a designer, and any code question needs the authority having jurisdiction.

Know what you need?

Send the specification and we will match it

Size, clear height, doors, power, heat and timing. We search the full Alberta record against it.

Submit a bay requirementSize it first